Sign In | Join Free | My himfr.com
Home > Ultrafiltration Membrane >

0.05um Ultrafiltration Membrane

Hangzhou Kaihong Membrane Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 0.05um Ultrafiltration Membrane from wholesalers
     
    Buy cheap 0.05um Ultrafiltration Membrane from wholesalers
    • Buy cheap 0.05um Ultrafiltration Membrane from wholesalers
    • Buy cheap 0.05um Ultrafiltration Membrane from wholesalers

    0.05um Ultrafiltration Membrane

    Ask Lasest Price
    Brand Name : CNKHONG
    Model Number : KH-UF-SFX2880
    Price : Negotiated
    Payment Terms : T/T
    Supply Ability : 50pieces/day
    Delivery Time : 10 days
    • Product Details
    • Company Profile

    0.05um Ultrafiltration Membrane

    SFX2880 Ulta-filtration Membrane Modules for Purified Water Treatment with Pore Size 0.05um PVDF material


    1. Brief Introduction

    Ultrafiltration (UF) is a type of membrane filtration in which hydrostatic pressure forces a liquid against a semipermeable membrane. A semipermeable membrane is a thin layer of material capable of separating substances when a driving force is applied across the membrane. Once considered a viable technology only for desalination, membrane processes are increasingly employed for removal of bacteria and other microorganisms, particulate material, and natural organic material, which can impart color, tastes, and odors to the water and react with disinfectants to form disinfection byproducts (DBP). As advancements are made in membrane production and module design, capital and operating costs continue to decline.

    Ultrafiltration (UF) systems have diverse membrane filtration where hydrostatic pressure pushes solvents against a very fine membrane. They block suspended particulates and solids that are large while water and solutes with a lower molecular weight are allowed to flow through the membrane.

    Industry and research employ this separation process for purifying and concentrating macromolecular (103 - 106 Da) solutions, which are usually protein solutions. Ultrafiltration is similar to microfiltration, nanofiltration or gas separation, except it differs in the molecule sizes it blocks.

    To meet critical discharge criteria, ultrafiltration systems remove the need for clarifiers and multi-media filters. Effective ultrafiltration systems use membranes that can be immersed, back-flushable, and air scoured. Spiral wound UF/MF membranes offer excellent performance for the clarification of process water and waste water.


    2. Description of ultrafiltration modules

    2.1 Module Features

    Our Ultrafiltration modules are made of high strength hollow fiber membranes, they are made of Polyvinylidene Fluoride(PVDF). The pore size of 0.03 µm is enough for the removal of bacteria, viruses, and particles including all kinds of colloids. v

    The membranes have been special treated to be hydrophilic. It is easy cleaning and wettability that help maintain long term performance. v Out to In flow configuration can endure high tolerance of feed solids. They also can be used pressed air to help the cleaning recovery.

    The dead-end filtration way offer higher recovery rate and energy savings. The largest water recovering rate can be more can 95%.


    2.2 Structure and Specifications of UF Membrane Modules

    2.2.1 Small size of UF modules

    aa.png


    Size and weight


    ModelKH-UF-4040W-PVDFKH-UF-6040W-PVDF
    Module Diameter ( A, mm)Φ90 mmΦ160 mm
    Module Length ( B, mm)960mm960mm
    Module Length (C, mm)1106 mm1304 mm
    Size of Inlet/Outlet (D, mm)DN25DN32
    Operating TypeOutside to InsideOutside to Inside
    Membrane Area8.0 m220 m2
    Dry weight of the module5 Kg12 Kg

    Parameters

    Shell materialUPVCUPVC
    Membrane MaterialPVDFPVDF
    Membrane pore size0.03μm0.03μm
    Inner diameter of the hollow fiber0.7 mm0.7 mm
    Outer diameter of the hollow fiber1.3mm1.3mm
    Turbidity of Permeating water≤ 0.2NTU≤ 0.2 NTU

    SDI value of permeating water


    ≤ 3≤ 3

    Flux rate of purified water

    (0.10MP,20℃)

    ≥1000L/H≥3000L/H

    Typical Process


    Temperature Range5-45 ℃5-45 ℃
    PH Value Range2-132-13

    Permeating Flux rate for different

    Water

    40 - 80 l/m2/hr40 -80 l/m2/hr
    Operating Pressure≤0.12 MPa≤0.12MPa
    Maximum Inlet Pressure0.2 MPa0.2MPa
    Backwashing flux rate

    1.5-2.0 times of

    Permeating Flux

    1.5-2.0 times of

    Permeating Flux

    Backwashing timesOnce per 30-120 minutesOnce per 30-120 minutes
    Chemical cleaning online during backwashingOnce per 7-14 daysOnce per 7-14 days


    The structure as the following:2.2.2 type A of 8 inches UF module.

    ab.png


    Size and weight


    ModelKH-UF-8040W-PVDFKH-UF-8060W-PVDF
    Module Diameter ( A, mm)Φ200 mmΦ200 mm
    Module Length ( B, mm)1220 mm1640 mm
    Module Length (C, mm)1365 mm1785 mm
    Size of Inlet/OutletDN50DN50
    Operating TypeOutside to InsideOutside to Inside
    Membrane Area30 m245 m2
    Dry weight of the module20 Kg35 Kg

    Parameters

    Shell materialUPVCUPVC
    Membrane MaterialPVDFPVDF
    Membrane pore size0.03μm0.03μm
    Inner diameter of the hollow fiber0.7 mm0.7 mm
    Outer diameter of the hollow fiber1.3mm1.3mm
    Turbidity of Permeating water≤ 0.2NTU≤ 0.2 NTU

    SDI value of permeating water


    ≤ 3≤ 3

    Flux rate for of purified water

    (0.10MP,20℃)

    ≥ 3600L/H≥ 5400L/H

    Typical Process


    Temperature Range5-45 ℃5-45 ℃
    PH Value Range2-132-13

    Permeating Flux rate for different

    Water

    40 - 80 l/m2/hr40 -80 l/m2/hr
    Operating Pressure≤0.12 MPa≤0.12MPa
    Maximum Inlet Pressure0.2 MPa0.2MPa
    Backwashing flux rate

    1.5-2.0 times of

    Permeating Flux

    1.5-2.0 times of

    Permeating Flux

    Backwashing timesOnce per 30-120 minutesOnce per 30-120 minutes
    Chemical cleaning online during backwashingOnce per 7-14 daysOnce per 7-14 days


    2.2.3 type B of 8 inches UF module. The structure as the following:

    ac.png


    Size and weight


    ModelKH-UF-SFX2860-PVDFKH-UF-SFX2880-PVDF
    Module Diameter (OD, mm)Φ225 mmΦ225 mm
    Module Length ( L1, mm)1500 mm2000 mm
    Module Length (L2, mm)1630 mm2130 mm
    Module Length (L3, mm)1820 mm2320 mm
    Module Length (L , mm)1860 mm2360 mm
    Operating TypeOutside to InsideOutside to Inside
    Membrane Area52 m277 m2
    Dry weight of the module42 Kg62 Kg

    Parameters

    Shell materialUPVCUPVC
    Membrane MaterialPVDFPVDF
    Membrane pore size0.03μm0.03μm
    Inner diameter of the hollow fiber0.7 mm0.7 mm
    Outer diameter of the hollow fiber1.3mm1.3mm
    Turbidity of Permeating water≤ 0.2NTU≤ 0.2 NTU

    SDI value of permeating water


    ≤ 3≤ 3

    Flux rate of purified water

    (0.10MP,20℃)

    ≥ 6500L/H≥ 8000L/H

    Typical Process


    Temperature Range5-45 ℃5-45 ℃
    PH Value Range2-132-13

    Permeating Flux rate for different

    Water

    40 - 80 l/m2/hr40 -80 l/m2/hr
    Operating Pressure≤0.12 MPa≤0.12MPa
    Maximum Inlet Pressure0.2 MPa0.2MPa
    Backwashing flux rate

    1.5-2.0 times of

    Permeating Flux

    1.5-2.0 times of

    Permeating Flux

    Backwashing timesOnce per 30-120 minutesOnce per 30-120 minutes
    Chemical cleaning online during backwashingOnce per 7-14 daysOnce per 7-14 days


    The whole installation and application process of our MBR modules are described as the following photo:


    0.05um Ultrafiltration Membrane0.05um Ultrafiltration Membrane



    Quality 0.05um Ultrafiltration Membrane for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Hangzhou Kaihong Membrane Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)